Reporting a Problem With a Medical Device

Reporting a Problem With a Medical Device
Prescription Medicines Editorial 28 February 2025

A great many medicines now arrive inside a device - an inhaler, an injection pen, a pump, a patch, an auto-injector. When something goes wrong it is frequently the device rather than the drug, and people tend to treat that as bad luck rather than something reportable. Device faults are reported through the same MHRA system as side effects, and the reporting is what identifies a batch or design problem.

What counts as a device problem

Inhalers - an actuator that does not fire, a dose counter reading incorrectly, a device that feels empty when the counter says otherwise, a blocked mouthpiece, a canister that will not seat.

Injection pens - a dial that sticks or will not turn, a plunger that will not depress, a dose that appears not to be delivered, leakage at the needle, a cracked cartridge, a needle cover that will not remove.

Auto-injectors - failure to fire, a needle that does not deploy, a device that activates prematurely.

Patches - failure to adhere, a pouch that has been damaged, a patch that falls off repeatedly.

Pumps and monitors - insulin pumps, continuous glucose monitors, blood glucose meters giving results inconsistent with how you feel, nebuliser compressors with reduced output.

Oral syringes and measuring devices - illegible or incorrect graduations.

Keep the device

The single most useful thing.

Do not throw it away, do not dismantle it, and do not clean it out.

The batch or lot number and the serial number are what allow a fault to be traced and other affected devices identified. Photograph the device and its packaging.

Take it back to the pharmacy that supplied it rather than binning it - they can quarantine stock from the same batch and report through professional channels.

See reporting a faulty or fake medicine.

Who to tell

The pharmacy first, who can replace it and report it.

The MHRA, through the Yellow Card scheme, which covers medical devices as well as medicines. Anyone can report - you do not need to be a health professional.

The manufacturer, who usually operates a customer line and will frequently replace the device and investigate.

Your specialist team for pumps, monitors and anything they supplied directly.

See how the Yellow Card scheme works.

Technique or fault?

Worth distinguishing, because a great many apparent device failures are technique.

Dry powder inhalers deliver no sensation, so people frequently believe a dose was not given when it was. Aerosol inhalers need a slow steady breath while dry powder devices need a hard fast one - and the two techniques are opposite, so a device switch produces apparent failure.

Pens need holding against the skin for a count after the click, and withdrawing early causes leakage that looks like device failure.

Ask for your technique to be checked before concluding the device is faulty - and ask to be shown any new device rather than assuming it works like the old one.

See when your inhaler or device changes and injecting yourself at home.

Why it matters more than it sounds

A device that does not deliver means a dose not taken, and for some treatments that is immediately serious.

An adrenaline auto-injector that fails during anaphylaxis, a reliever inhaler that is empty during an attack, an insulin pump that stops overnight - these are the scenarios the reporting system exists to prevent.

That is also the argument for carrying two auto-injectors, checking inhaler counters, and knowing the pump's emergency plan.

See adrenaline auto-injectors.

Recalls and safety notices

When a device problem is confirmed, the MHRA issues a field safety notice or a device alert specifying affected batches and what to do.

These reach pharmacies, practices and hospitals, and sometimes users directly where devices are registered.

Register your device with the manufacturer where that is offered - it is how you get told.

If you are contacted about a device recall, do not simply stop using it until you have a replacement, unless the notice says otherwise. Ask what to use meanwhile.

See when a medicine is withdrawn for safety.

Devices you buy yourself

Blood pressure monitors, thermometers, pulse oximeters and home test kits are devices too, and faults in these are equally reportable.

Choose a validated blood pressure monitor rather than the cheapest - unvalidated devices give readings that look plausible and are not, which leads to wrong decisions in both directions.

Anything bought from an unregulated overseas seller carries no assurance at all.

See buying health devices and tests online.

Disposal

Once a faulty device has been reported and you have been told it is no longer needed, dispose of it properly.

Pens and auto-injectors go in a sharps bin. Inhalers go back to a pharmacy, since even empty ones retain propellant. Electronic devices and batteries follow electrical waste rules.

See needles and sharps disposal.

More on side effects and safety in the Side Effects section, including Reporting a Side Effect in Pregnancy.